UL3134 is a member of the UL wire family, rated 150℃ and 600V.
Parameters
- Style number: UL3134
- Rated temperature: 150℃
- Rated voltage: 600V
- Conductor material: stranded copper, or solid copper
- Insulation material: quality silicone rubber
- Use standard: AWM, UL758, UL3134
- Application: internal wiring of electrical appliance.
Specification
UL3134 | Wire Gauge | Conductor Structure | Insulation Thickness |
Overall Diameter |
Standard Package | Minimum Package | Conductor Resistance |
(Cond Type) | (AWG) | (No/mm) | (mm) | (mm) | (Feet) | (Meters) | (Ω/KM) |
Stranded | 18 | 7/0.39 | 0.76 | 2.75 | 2000 | 610 | 23.20 |
Stranded | 18 | 34/0.178 | 0.76 | 2.75 | 2000 | 610 | 23.20 |
Stranded | 16 | 7/0.50 | 0.76 | 3.09 | 1000 | 305 | 14.60 |
Stranded | 16 | 26/0.25 | 0.76 | 3.09 | 1000 | 305 | 14.60 |
Stranded | 14 | 37/0.26 | 0.76 | 3.44 | 1000 | 305 | 8.96 |
Stranded | 14 | 41/0.25 | 0.76 | 3.44 | 1000 | 305 | 8.96 |
Stranded | 12 | 45/0.32 | 0.76 | 4.00 | 1000 | 305 | 5.64 |
Stranded | 12 | 65/0.25 | 0.76 | 4.00 | 1000 | 305 | 5.64 |
Solid | 18 | 1/1.02 | 0.76 | 2.75 | 2000 | 610 | 21.80 |
Solid | 16 | 1/1.29 | 0.76 | 3.09 | 1000 | 305 | 13.70 |
Solid | 14 | 1/1.63 | 0.76 | 3.44 | 1000 | 305 | 8.62 |
Solid | 12 | 1/2.05 | 0.76 | 4.00 | 1000 | 305 | 5.43 |